Reference Mode (rEF)
40
S1A28692 04/2010
Parameters described in this page can be accessed by:
Menu
(1) It is not necessary to press the ENT key to confirm the modification of the reference.
Code Name / Description Adjustment range Factory setting
drI- [1 DRIVE MENU]
rEF- [1.1 SPEED REFERENCE]
Displayed parameters depend on drive settings.
AIU1
g
T
(1)
[Image input AIV1]
0 to 100% of HSP-LSP 0%
First virtual AI value.
This parameter allows to modify the frequency reference with the embedded jog dial.
LFr
g
T
(1)
[HMI Frequency ref.]
-599 to +599 Hz 0 Hz
HMI frequency reference (signed value).
This parameter allows to modify the frequency reference with the remote HMI.
MFr [Multiplying coeff.]
0 to 100% 100%
g
T
Multiply frequency variable.
Multiplying coefficient, can be accessed if [Multiplier ref.-] (MA2,MA3) page 154
has been assigned to the graphic terminal.
rPI [Internal PID ref.]
0 to 32,767 150
g
T
(1)
PID: Internal reference PI.
This parameter allows to modify the PID internal reference with the jog dial.
Internal PID reference is visible if [PID feedback] (PIF) is not set to [No] (nO).
FrH [Frequency ref.]
-599 to +599 Hz -
g
Frequency reference before ramp (signed value).
Actual frequency reference applied to the motor regardless of which reference channel has been selected. This parameter is in
read-only mode.
Frequency reference is visible if the command channel is not HMI or virtual AI.
rPC [PID reference]
0 to 65,535 -
g
PID: Setpoint value.
PID reference is visible if [PID feedback] (PIF) is not set to [No] (nO).
g
These parameters only appear if the corresponding function has been selected in another menu. When the parameters can
also be accessed and adjusted from within the configuration menu for the corresponding function, their description is detailed
in these menus, on the pages indicated, to aid programming.
T
Parameter that can be modified during operation or when stopped.
DRI- > REF-
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Vue de la page 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 ... 318 319

Commentaires sur ces manuels

Pas de commentaire