Configuration Mode (ConF)
250 S1A28692 03/2010
Parameters described in this page can be accessed by:
Card pairing
Function can only be accessed in [Expert]
(EPr) mode.
This function is used to detect whenever a card has been replaced or the software has been modified in any
way.
When a pairing password is entered, the parameters of the card currently inserted are stored. On every
subsequent power-up, these parameters are verified and, in the event of a discrepancy, the drive locks in HCF
fault mode. Before the drive can be restarted, you must revert to the original situation or re-enter the pairing
password.
The following parameters are verified:
The type of card for: all cards.
The software version for: the control block, the communication cards.
The serial number for: the control block.
Code Name / Description Adjustment range Factory setting
FLt- [FAULT MANAGEMENT] (continued)
PPI- [CARDS PAIRING]
PPI
[Pairing password]
[OFF] (OFF) to 9,999 [OFF] (OFF)
g
OFF
-
The [OFF] (OFF) value signifies that the card pairing function is inactive
The [ON] (On) value signifies that card pairing is active and that an access code must be entered in order to start the drive in
the event of a card pairing detected fault
As soon as the code has been entered, the drive is unlocked and the code changes to [ON] (On).
The PPI code is an unlock code known only to Schneider Electric Product Support.
g
These parameters only appear if the corresponding function has been selected in another menu. When the parameters can
also be accessed and adjusted from within the configuration menu for the corresponding function, their description is detailed