Schneider Electric Altivar 32 Manuel d'installation Page 31

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 88
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 30
CiA
®
402 - IEC61800-7 Functional Profile
S1A28702 05/2010 31
Status Word (EtA)
(1) This mask can be used by the PLC program to test the chart state.
(2) Detected fault following state "6 - Quick stop active".
x: In this state, the value of the bit can be 0 or 1.
bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0
Warning Switch on
disabled
Quick stop Voltage
enabled
Fault Operation
enabled
Switched on Ready to switch
on
Alarm Power section
line supply
disabled
0 = Emergency
stop
Power section
line supply
present
Fault Running Ready 1 = Awaiting
power section
line supply
bit 15 bit 14 bit 13 bit 12 bit 11 bit 10 bit 9 bit 8
Manufacturer
specific
Direction of
rotation
Manufacturer
specific
Stop via STOP
key
Reserved (=0) Reserved (=0) Internal limit
active
Target reached Remote Reserved (=0)
Reference
outside limits
Reference
reached
Command or
reference via
network
Status bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 ETA
masked by
16#006F
(1)
Switch on
disabled
Quick stop Voltage
enabled
Fault Operation
enabled
Switched
on
Ready to
switch on
1 -Not ready to
switch on
0xx0000-
2 -Switch on
disabled
1 x x 0 0 0 0 16#0040
3 -Ready to switch
on
0 1 x 0 0 0 1 16#0021
4 -Switched on 0 1 1 0 0 1 1 16#0023
5 -Operation
enabled
0 1 1 0 1 1 1 16#0027
6 -Quick stop active 0 0 1 0 1 1 1 16#0007
7 -Fault reaction
active
0xx1111-
8 -Fault 0 x x 1 0 0 0
16#0008
(2)
or 16#0028
Vue de la page 30