Power Meter 750 63230-507-201A1
Section 3—Operation 03/2007
© 2007 Schneider Electric All Rights Reserved10
Set Up Communications
Set Up the Bar Graph Scale
1. In SETUP mode, press ###: until COM
is visible.
2. Press COM.
3. Enter the ADDR (meter address): 1 to
247.
4. Press OK.
5. Select the BAUD (baud rate): 2400, 4800,
9600, or 19200.
6. Press OK.
7. Select the parity: EVEN, ODD, or NONE.
8. Press OK to return to the SETUP MODE
screen.
NOTE: Default values are displayed.

#/-3%450
 /+

%UDM
A@T$
0@Q
LATR
!$$2
1. In SETUP mode, press ###: until BARG
is visible.
2. Press BARG.
3. Enter the %CT (percent of CT primary to
represent 100 on the bar graph).
4. Press OK to return to the SETUP MODE
screen.

"!2'2!0(3#!,%
 /+


#4
!
LATR
!$$2
