Technical Data
ACRD100
ACRD101
ACRD200
ACRD201
ACRD500
ACRD501
ACRD502
InRow
®
RD
Air-Cooled/Fluid-Cooled - 50/60 Hz
Vue de la page 0
1 2 3 4 5 6 ... 14 15

Résumé du contenu

Page 1 - Technical Data

Technical DataACRD100ACRD101ACRD200ACRD201ACRD500ACRD501ACRD502InRow® RDAir-Cooled/Fluid-Cooled - 50/60 Hz

Page 2

InRow RD Technical Data Manual4Standard FeaturesCabinetThe frame is constructed of 16 gauge formed steel for maximum strength. The cabinet is servicea

Page 3 - Contents

5InRow RD Technical Data ManualOptional FeaturesCable Water DetectorA leak detection cable is placed on the floor or subfloor around all possi-ble lea

Page 4

InRow RD Technical Data Manual6Microprocessor ControllerMicroprocessor Controller The microprocessor controller is standard on each unit. The controll

Page 5

7InRow RD Technical Data ManualAlarmsThe microprocessor controller shall activate a visible and audible alarm in the following occurrences:All series:

Page 6

InRow RD Technical Data Manual8InRow RD ModelsExterior components: ACRD100 and ACRD200 seriesRemovable rear doorAdjustable leveling feetSide panel

Page 7 - Overview

9InRow RD Technical Data ManualInterior components (front): ACRD100 seriesElectrical control box 1 (retractable)CompressorElectrical control box 2

Page 8 - Scalable for High Density

American Power Conversion Legal DisclaimerThe information presented in this manual is not warranted by the American Power Conversion Corporation to be

Page 9 - Hot Aisle Containment System

ContentsInRow RD Technical Data ManualiOverview ... 1Scalable Solution for Crit

Page 10 - Standard Features

InRow RD Technical Data ManualiiPerformance Specifications ... 19Net Cooling Capacity (Air and Glycol Cooled) .

Page 11 - Optional Features

InRow RD Technical Data ManualiiiGuide Specifications ...43Guidelines for Installation . . . . . .

Page 13

1InRow RD Technical Data ManualOverviewThe modular, row-based computer room cooling system offers efficient, predictable, and economical cooling for a

Page 14 - InRow RD Models

InRow RD Technical Data Manual2Scalable Solution for Critical EnvironmentsInRow AdvantagesThe row-based solution improves energy efficiency and coolin

Page 15

3InRow RD Technical Data ManualHot Aisle Containment System Modular ceiling tiles and doors can be used to enclose the hot aisle. This increases the d