Vue de la page 34
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
33
Combinations (continued)
Variable speed drives
Altivar 32
Motor starters: circuit-breaker + contactor + drive
Motor starters: circuit-breaker + contactor + drive
Standard
power rating
of 50/60 Hz
4-pole
motors (3)
Variable speed
drive
Circuit-breaker
(1)
Contactor
(2)
Reference Reference Rating Maximum
short-circuit
current Icu
at 415 V
Reference
(4)
kW HP A
Single-phase supply voltage: 200…240 V 50/60 Hz
0.18
1/4
ATV 32H018M2 GV2 L08 4
> 100
LC1 D09pp
0.37
1/2
ATV 32H037M2 GV2 L10 6.3
> 100
LC1 D09pp
0.55
3/4
ATV 32H055M2 GV2 L14 10
> 100
LC1 D09pp
0.75
1
ATV 32H075M2 GV2 L16 14
> 100
LC1 D09pp
1.1
1
1/2
ATV 32HU11M2 GV2 L16 14
> 100
LC1 D09pp
1.5
2
ATV 32HU15M2 GV2 L20 18
> 100
LC1 D09pp
2.2
3
ATV 32HU22M2 GV2 L22 25
50
LC1 D09pp
Three-phase supply voltage: 380…500 V 50/60 Hz
0.37
1/2
ATV 32H037N4 GV2 L07 2.5
> 100
LC1 D09pp
0.55
3/4
ATV 32H055N4 GV2 L08 4
> 100
LC1 D09pp
0.75
1
ATV 32H075N4 GV2 L08 4
> 100
LC1 D09pp
1.1
1
1/2
ATV 32HU11N4 GV2 L10 6.3
> 100
LC1 D09pp
1.5
2
ATV 32HU15N4 GV2 L14 10
> 100
LC1 D09pp
2.2
3
ATV 32HU22N4 GV2 L14 10
> 100
LC1 D09pp
3
ATV 32HU30N4 GV2 L16 14
50
LC1 D09pp
4
5
ATV 32HU40N4 GV2 L16 14
50
LC1 D09pp
5.5
7
1/2
ATV 32HU55N4 GV2 L22 25
50
LC1 D09pp
7.5
10
ATV 32HU75N4 GV2 L32 32
50
LC1 D18pp
11
15
ATV 32HD11N4 GV3 L40 40
50
LC1 D25pp
15
20
ATV 32HD15N4 GV3 L50 50
50
LC1 D32pp
(1) GV2 L, GV3 L: TeSys magnetic motor circuit-breakers; accessories (see page 35).
(2) Composition of TeSys contactors LC1 D09/D18/D25/D32 :
3 poles + 1 N/O auxiliary contact + 1 N/C auxiliary contact.
(3) The HP values given are NEC-compliant (National Electrical Code).
(4) Replace pp with the control circuit voltage reference given in the table below:
AC control circuit
Volts a 24 48 115 230 230/240
LC1-D 50/60 Hz B7 E7 FE7 P7 U7
For other voltages between 24 V and 660 V, or a DC control circuit, please refer to the “Motor
starter solutions - Control and protection components" catalogue or visit
www.schneider-electric.com.
GV2 L14
+
LC1 D09
+
ATV 32HU15N4