Schneider Electric Xantrex TR1512 230 50 Spécifications

Naviguer en ligne ou télécharger Spécifications pour Adaptateurs et onduleurs de puissance Schneider Electric Xantrex TR1512 230 50. Schneider Electric Xantrex TR1512 230 50 Specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 72
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
B
Schneider Electric
renewable energies
catalog
> Solar
inverters
>
Solar inverter/chargers
>
System components
>
Accessories
> Solutions
Vue de la page 0
1 2 3 4 5 6 ... 71 72

Résumé du contenu

Page 1 - Schneider Electric

BSchneider Electricrenewable energies catalog> Solar inverters> Solar inverter/chargers> System components > Accessories> Solutions

Page 3 - Contents

10String inverter solutions

Page 4 - Renewable Energies

11SunEzy VDE, RD, DK (indoor)Models VDE-RD SunEzy 2000 SunEzy 2800 SunEzy 3000 / 3043 SunEzy 4000Reference PVSNV12000 PVSNV12800 PVSNV13000 PV

Page 5 - Make the most of your energy

12> Solar invertersSunEzy VDE, RD, DK (indoor) Grid Tie InvertersSunEzyofferisasystemfortheinterconnectionofPhotovoltaicmodules, for DC

Page 6 - Installer Training

13SunEzy VDE, RD, DK (outdoor)Models VDE-RD SunEzy 400E SunEzy 600E SunEzy 6065Reference PVSNV1400E PVSNV1600E PVSNV16065Models DK SunEzy 4065

Page 7 - > Three-Phase:

14SunEzy VDE, RD, DK (outdoor) Grid Tie InvertersSunEzyofferisasystemfortheinterconnectionofPhotovoltaicmodules, for DC/AC power conversion

Page 8 - Basic grid-tie system

15Xantrex™ GT InvertersElectrical specificationsModels GT2.8 SP GT3.8 SP GT5.0 SPMaximumACpoweroutput 2800W 3800W 5000WNominalACpowero

Page 9 - Commercial

16Xantrex™ GT Series Grid Tie Inverters (Spain)High performance string inverters•From2,8kWto5,0kW•SuperiorPVenergyharvest•Peakinverteref

Page 10

17Xantrex™ Grid Tie Solar InvertersElectrical specifications Models GT2.8 AU GT5.0 AUOutputMaximumACpoweroutput 2800W 5000WNominalACvoltag

Page 11 - String inverter

18Xantrex™ GT Series Grid Tie Inverters (Australia)Xantrex inverters make installation easy and affordableWhenXantrexsetouttodeveloptheGridTi

Page 13 - Grid Tie Inverters

19Schneider Electric Conext™ Grid Tie InvertersElectrical specifications - outputModels 5000 W 3800 W 3300W 2800WNominaloutputpower 5000W/45

Page 14 - SunEzy VDE, RD, DK (outdoor)

20> Solar invertersSchneider Electric Conext™ Grid Tie Inverters (North America)ThenewSchneiderElectricConextGridTieinverterhasbeenrede

Page 15

21Xantrex™ GT Series InvertersElectrical specifications - outputModels GT5.0 GT4.0 N GT3.8 GT3.3 N GT2.8 Nominaloutpu

Page 16 - Xantrex™ GT Inverters

22> Solar invertersXantrex™ GT Series Grid Tie Inverters (North America)Technology•AnNECcompliant,integratedDC/ACdisconnect,standardinth

Page 18 - Electrical specifications

24Central inverter solutions

Page 19

25Xantrex™ GT30 E InverterElectrical specificationsNominalpowerrating(AC) 29,9kWMaxcontinuouspower(AC) 32,9kWNominalACvoltage 400V,th

Page 20 - Grid Tie Inverters

26Schneider Electric Xantrex™ GT30 E Grid Tie Solar Inverter High-efficiency isolated HF design•Oneofthehighestefcienciesinthe30kWclass•

Page 21 - Available

27Xantrex™ GT30 InvertersElectrical specificationsNominalpowerrating(AC) 28.8kWMaximumpoweroutput(AC) 30kWMaximumcontinuousACcurrent 8

Page 22 - GT Series Inverters

28> Solar invertersSchneider Electric Xantrex™ GT30 Grid Tie Solar InverterFeatures• Transformerless design with high peak and CEC efficiency•Bip

Page 23

2About Schneider Electric 3-4Schneider Electric Professional 5-6 Installer TrainingString inverter solutions 10Solar inverters (single-phase) •S

Page 24

29Xantrex™ GT100 E InverterElectrical specificationsContinuouspowerrating 100kWACNominalDCpowerrating 105kWDCNominalACvoltage 400Vac

Page 25 - Central inverter

30Schneider Electric Xantrex™ GT100 E Grid Tie Solar InverterFeatures•DigitalSignalProcessor(DSP)basedcontrolswithself-diagnostics and LCD

Page 26 - GT30 E Inverter

31Xantrex™ GT100 and GT250 InvertersElectrical specificationsModels GT100 208 GT100 480 GT100 600 (preliminary) GT250 480 GT250 600 (preliminary)

Page 27 - Schneider Electric Xantrex

32> Solar invertersSchneider Electric Xantrex™ GT100 and GT250 Grid Tie Solar InvertersFeatures•Ultra-efcientdesignwithindustry-leadingCEC

Page 28 - GT30 Inverters

33Xantrex™ GT250 E, GT500 E, and GT630 EElectrical specifications Models GT250 E GT500 E GT630 EContinuouspowerrating 250kWAC 500kWAC 63

Page 29 - GT30 Grid Tie Solar Inverter

34> Solar invertersSchneider Electric Xantrex™ GT250 E, GT500 E, and GT630 E Grid Tie Solar InvertersFeatures•DigitalSignalProcessor(DSP)bas

Page 30 - Regulatory approvals

35Xantrex™ GT500 InvertersElectrical specificationsModels GT500 480 (preliminary) GT500 600 (preliminary) GT500 MVXMaximumcontinuousoutputpower

Page 31

36> Solar invertersSchneider Electric Xantrex™ GT500 Grid Tie Solar InverterFeatures•Ultra-efcientdesignwithCECefciencyof97%(GT500MVX

Page 32 - GT100 and GT250 Inverters

37PV BOX EuropeAdditional Features• Integrated medium voltage switchgear providing grid-connection and transformer feeder with circuit-breaker•Mee

Page 33 - Solar Inverters

38> SolutionsCentral invertersPV BOXTheSchneiderElectricPVBOXisapre-wiredequipmentpackagefortheEuropeanandNorthAmericanmarket,spec

Page 34

3The history of Schneider ElectricSchneider Electric, founded in 1836, has transformed itself into the global specialist in energy management. From it

Page 35 - Grid Tie Solar Inverters

39EngineeringProjectOperation Presalessupport Design, architecture and lay-out Electrical protection and selectivity study Lightning protection

Page 36 - GT500 Inverters

40Solucionesde aislada y back-upEólicaSolarHidráulicaRedGeneradorEnergía de respaldo (back-up)Fuentes CAXanbus™Arranque generador(AGS)Inversor/Cargado

Page 37 - GT500 Grid Tie Solar Inverter

Residential off-grid systemResidential backup systemXantrex XW SystemXantrex TRResidentialbackup system41Basic off-grid systemWithanoff-gridsystem,

Page 38 - PV BOX North America

Residential off-grid systemResidential backup systemXantrex XW SystemXantrex TRResidentialoff-grid system42

Page 40 - Turnkey solutions

44Off-grid and backup products and solutions

Page 42 - Basic off-grid system

46Schneider Electric Xantrex™ TR Series Inverter/ChargersThe TR Series Inverter/Charger is an economical power conversion solution designed to provid

Page 43 - Residential

47Xantrex™ TR Series Inverter/Chargers 230 V 50 HzElectrical specificationsModels TR1512 230 50 TR1524 230 50 TR2424 230 50Continuousoutputpower

Page 44

48Xantrex™ TR Series Inverter/Chargers 120 V 60 HzElectrical specificationsModels TR1512 120 60 TR2412 120 60 TR1524 120 60 TR2424 120 60 TR3624

Page 45 - Off-grid and backup

4>For more information about Schneider Electric and renewable energy solutions, please visit www.schneider-electric.comMake the most of your ene

Page 47 - TR Series Inverter/Chargers

50Schneider Electric Xantrex™ XW Inverter/ChargerFeatures• True sine-wave output•Highsurgecapacity–innovativeFullDigitalControlregulatesvol

Page 48

51Xantrex™ XW Series Inverter/Chargers 230 V 50 HzElectrical specificationsModels XW6048 230 50 XW4548 230 50 XW4024 230 50Continuousoutputpower

Page 49

52Xantrex™ XW Series Inverter/Chargers 120/240 V 60 HzElectrical specificationsModels XW6048 120240 60 XW4548 120240 60 XW4024 120240 60Continuous

Page 50

53Schneider Electric Xantrex™ XW MPPT 60 150 Solar Charge ControllerElectrical specificationsNominalbatteryvoltage 12,24,36,48,60VdcMaximumP

Page 51 - XW Inverter/Charger

54Schneider Electric Xantrex™ XW MPPT 60 150 Solar Charge ControllerTheXantrexXWMPPT60150isaphotovoltaic(PV)chargecontroller thattracks

Page 52 - Regulatory approval

55Schneider Electric Xantrex™ XW MPPT 80 600 Solar Charge Controller Electrical specifications Nominalbatteryvoltage 24and48VDC(Defaultis48

Page 53 - > Solar inverter/chargers

56Schneider Electric Xantrex™ XW MPPT 80 600 Solar Charge ControllerTheXantrexXWMPPT80600isaphotovoltaic(PV)ChargeController thattracks

Page 54

57Xantrex™ C12 PWM Charge ControllerElectrical specificationsMaximumPVamps 12Aat12VdconlyMaximumDCload 12AwithautoresetMinimumoperatin

Page 55 - Controller

58Schneider Electric Xantrex™ C12 PWM Charge ControllerTheC12PWMcharge,lighting,orloadcontrollerisuniquelysophisticated. As a charge contr

Page 56

5Schneider Electric Professional Installer TrainingSchneider Electric offers training for both the Schneider Electric Single-Phase and Three-Phase s

Page 57

59Xantrex™ C Series Charge ControllersElectrical specificationsModels C35 PWM C40 PWM C60 PWMVoltageconfigurations 12and24Vdc 12,24,and48

Page 58 - C12 PWM Charge Controller

60Schneider Electric Xantrex™ C Series ControllerTheSchneiderElectricXantrexC35PWMandC60PWMareeldcongurablefor12-and24-Vdcoperatio

Page 60 - C Series Charge Controllers

62Accessories and protection

Page 61 - C Series Controller

63Xantrex™ GatewayElectrical specificationsCommunication Physicallayer2,CANCommunicationprotocol Xanbus™MaximumXanbuscablelength 40mMaxi

Page 62

64Schneider Electric Xantrex™ GatewayTheXantrexGatewaybridgesthegapbetweenaXantrexGTorXWSystemandthesystemowner’scomputer,makingit

Page 63 - and protection

65For use with single or multi-inverterPVsystemForusewithXantrex C Series Charge Controllers> AccessoriesBattery Temperature SensorTheBTSm

Page 64 - Gateway

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products conta

Page 65

67Alternating current (AC)The type of electricity supplied by the utility company. The unique characteristic of this form of electricity is that itr

Page 66 - > Accessories

68> Glossary of termsLine lossA voltage drop caused by resistance in wire during transmission of electrical power over distance.LoadAny device th

Page 67

6> TrainingSchneider Electric Three-Phase Training: > Three-Phase:This training is a comprehensive course for the system operators of larger sol

Page 68

69At Schneider Electric Renewable Energies,customersatisfactionis everyone's number one priority

Page 70

©2010 Schneider Electric. All rights reserved. Schneider Electric, Schneider Electric logo, Xantrex, Xanbus, Conext, and Square D are trademarks or re

Page 71

Small utility solarResidential grid-tie solarPV power plantGT SeriesGT30 / GT30 ESmall commercial scaleGT SeriesXantrex XW SystemSunEzy SeriesResiden

Page 72 - The mark IEEE Std 802.3-2005

Small utility solarResidential grid-tie solarPV power plantGT250 / GT250 EGT500 / GT500 EGT630 EUtilityscaleGT100 / GT100 EGT250 / GT250 ECommercialsc

Commentaires sur ces manuels

Pas de commentaire